Julita, Sari (2025) ANALISA HARMONISA DAN RANCANG FILTER SINGLE TUNED PADA SISTEM IEEE 16 BUS MENGGUNAKAN SOFTWARE ETAP 19.0.1. Bachelor thesis, Institut Teknologi Kalimantan.
![]() |
Text
04191038_Statement_of_outhenticity.pdf Restricted to Repository staff only until 4 October 2027. Download (182kB) | Request a copy |
![]() |
Text
04191038_Statement_of_outhenticity.pdf Restricted to Repository staff only until 4 October 2027. Download (182kB) | Request a copy |
![]() |
Text
04191038-Cover.pdf Restricted to Repository staff only Download (189kB) | Request a copy |
![]() |
Text
04191038-Cover.pdf Restricted to Repository staff only until 4 October 2027. Download (189kB) | Request a copy |
![]() |
Text
04191038_Approval_sheet.pdf Download (284kB) |
![]() |
Text
04191038_Publishin_agreement.pdf Download (245kB) |
![]() |
Text
04191038_Preface.pdf Download (189kB) |
![]() |
Text
0419103_Chapter_3.pdf Restricted to Repository staff only until 4 October 2027. Download (461kB) | Request a copy |
![]() |
Text
04191038_Abstrak_id.pdf Download (239kB) |
![]() |
Text
04191038_Anstrak_en.pdf Restricted to Repository staff only until 4 October 2027. Download (238kB) | Request a copy |
![]() |
Text
04191038_Bibliography.pdf Download (197kB) |
![]() |
Text
04191038_Chapter_1.pdf Restricted to Registered users only until 4 October 2027. Download (318kB) | Request a copy |
![]() |
Text
04191038_Chapter_2.pdf Restricted to Repository staff only until 4 October 2027. Download (576kB) | Request a copy |
![]() |
Text
04191038_Chapter_4.pdf Restricted to Repository staff only until 4 October 2027. Download (1MB) | Request a copy |
![]() |
Text
04191038_Conclusions.pdf Restricted to Repository staff only until 4 October 2027. Download (274kB) | Request a copy |
![]() |
Text
04191038_Enclosure.pdf Restricted to Repository staff only until 4 October 2027. Download (648kB) | Request a copy |
![]() |
Text
04191038_Notations.pdf Restricted to Repository staff only until 4 October 2027. Download (137kB) | Request a copy |
![]() |
Text
04191038_Preface.pdf Restricted to Repository staff only until 4 October 2027. Download (189kB) | Request a copy |
![]() |
Text
04191038_Paper.pdf Restricted to Repository staff only until 4 October 2027. Download (1MB) | Request a copy |
![]() |
Text
04191038_Form.TA-20.pdf Restricted to Repository staff only until 4 October 2027. Download (243kB) | Request a copy |
![]() |
Text
04191038_Table_of_content.pdf Restricted to Repository staff only until 4 October 2027. Download (244kB) | Request a copy |
![]() |
Text
04191038-Tables.pdf Restricted to Repository staff only until 4 October 2027. Download (223kB) | Request a copy |
![]() |
Text
04191038_Illustrations.pdf Restricted to Repository staff only until 4 October 2027. Download (223kB) | Request a copy |
![]() |
Text
04191038_Presentation.pdf Restricted to Repository staff only until 4 October 2027. Download (0B) | Request a copy |
![]() |
Text
04191038_Statement_of_Authenticity.pdf Download (53kB) |
Abstract
Seiring banyaknya penggunaan listrik maka perlu diperhatikan peralatan listrik yang terus bekerja dalam menyalurkan listrik, dalam penyaluran listrik peralatan listrik memilki masalah atau gangguan salah satunya yaitu gangguan harmonisa. Gangguan Harmonisa disebabkan oleh pemakain Beban Non Linier yang membuat kualitas listrik yang diberikan menjadi kurang sehingga terjadinya rugi rugi daya. Untuk mengatasi gangguan harmonisa salah satu Solusi yang dapat digunakan yaitu pemasangan filter. Filter yang digunakan dalam penelitian ini yaitu filter single tuned yang dapat mengatasi gangguan harmonisa dan rugi – rugi daya. Dalam penggunaan filter single tuned sistem yang digunakan yaitu Sistem IEEE 16 Bus. Sistem IEEE 16 Bus digunakan sebagai Rangkaian simulasi yang sudah berstandar IEEE Std. 519- 2014. Dari hasil simulasi didapatkan pengaruh dari pemasangan beban non linier berupa UPS (Uninterruptible Power Supply) dan filter single tuned yang menunjukan bahwa dengan adanya pemasangan beban non linier mengakibatkan nilai THD (Total Harmonic Distortion) mengalami kenaikan sebesar 5.80% - 5.82% dan meningkatnya rugi – rugi daya dari 732.5 kW menjadi 789.1 kW. Dilakukan beberapa percobaan di bus 1, bus 7 dan bus 15 dalam penurunan gangguan harmonisa dan rugi – rugi daya, didapatkan hasil yang optimal dalam penempatan filter single tuned di sistem IEEE 16 bus yaitu di bus 1 dan bus 7 dengan hasil penurunan gangguan harmonisa sebesar 2.92% - 2.93% dan penurunan rugi – rugi daya 783.1 kW.
Item Type: | Thesis (Bachelor) |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Jurusan Teknologi Industri dan Proses > Teknik Elektro |
Depositing User: | Julita Sari |
Date Deposited: | 17 Jul 2025 06:53 |
Last Modified: | 17 Jul 2025 06:53 |
URI: | http://repository.itk.ac.id/id/eprint/24656 |
Actions (login required)
![]() |
View Item |