RANCANG BAGUN ALAT UKUR KADAR ALKOHOL PADA PARFUM MENGGUNAKAN SENSOR INGAAS PHOTODIODA BEBRSIS MIKROKONTROLER

Simangunsong, Russel Amanda (2026) RANCANG BAGUN ALAT UKUR KADAR ALKOHOL PADA PARFUM MENGGUNAKAN SENSOR INGAAS PHOTODIODA BEBRSIS MIKROKONTROLER. Bachelor thesis, Institut Teknologi Kalimantan.

[img] Text
04211075_Abstract_en.pdf
Restricted to Repository staff only until 10 April 2028.

Download (347kB) | Request a copy
[img] Text
04211075_Abstract_en.pdf
Restricted to Repository staff only until 10 April 2028.

Download (347kB) | Request a copy
[img] Text
04211075_Abstract_id.pdf
Restricted to Repository staff only until 10 April 2028.

Download (309kB) | Request a copy
[img] Text
04211075_Bibliography.pdf
Restricted to Repository staff only until 10 April 2028.

Download (364kB) | Request a copy
[img] Text
04211075_Chapter_1.pdf
Restricted to Repository staff only until 10 April 2028.

Download (491kB) | Request a copy
[img] Text
04211075_Chapter_2.pdf
Restricted to Repository staff only until 10 April 2028.

Download (807kB) | Request a copy
[img] Text
04211075_Chapter_3.pdf
Restricted to Repository staff only until 10 April 2028.

Download (723kB) | Request a copy
[img] Text
04211075_Chapter_4.pdf
Restricted to Repository staff only until 10 April 2028.

Download (698kB) | Request a copy
[img] Text
04211075_Conclusions.pdf
Restricted to Repository staff only until 10 April 2028.

Download (364kB) | Request a copy
[img] Text
04211075_Form_20.pdf
Restricted to Repository staff only until 10 April 2028.

Download (1MB) | Request a copy
[img] Text
04211075_Illustrations.pdf
Restricted to Repository staff only until 10 April 2028.

Download (317kB) | Request a copy
[img] Text
04211075_Notations.pdf
Restricted to Repository staff only until 10 April 2028.

Download (295kB) | Request a copy
[img] Text
04211075_Paper.pdf
Restricted to Repository staff only until 10 April 2028.

Download (703kB) | Request a copy
[img] Text
04211075_Preface.pdf
Restricted to Repository staff only until 10 April 2028.

Download (328kB) | Request a copy
[img] Text
04211075_Table_of_Content.pdf
Restricted to Repository staff only until 10 April 2028.

Download (367kB) | Request a copy
[img] Text
04211075_Tables.pdf
Restricted to Repository staff only until 10 April 2028.

Download (334kB) | Request a copy
[img] Text
04211075_Presentation.pdf
Restricted to Repository staff only until 10 April 2028.

Download (1MB) | Request a copy
[img] Text
04211075_Presentation.pdf
Restricted to Repository staff only until 10 August 2028.

Download (1MB) | Request a copy
[img] Text
04211075_Aproval_Sheet.pdf
Restricted to Repository staff only until 10 April 2028.

Download (1MB) | Request a copy
[img] Text
04211075_Publishing_Agreement.pdf
Restricted to Repository staff only until 10 April 2028.

Download (2MB) | Request a copy
[img] Text
04211075_Statement_of_Authenticity.pdf
Restricted to Repository staff only until 10 April 2028.

Download (1MB) | Request a copy
[img] Text
04211075_Cover.pdf
Restricted to Repository staff only until 10 April 2028.

Download (518kB) | Request a copy

Abstract

The perfume industry requires precise raw material composition to achieve optimal product characteristics, such as sillage, longevity, and projection. One of the primary ingredients in perfume formulation is patchouli oil (minyak nilam), which is frequently blended with alcohol. Therefore, an instrument capable of accurately and efficiently measuring alcohol concentration in perfume is essential to ensure product safety for consumers. This study aims to design a device to measure alcohol concentration in perfume using an InGaAs Photodiode detector integrated with a 1300 nm LED light source. The measurement process utilizes the Near-Infrared (NIR) method, employing near-infrared light at a wavelength of 1300 nm to detect the alcohol content within the samples. The experimental results yielded specific absorbance values for each perfume sample tested. For the Extrait de Parfum sample, which contained the lowest alcohol concentration, the absorbance values ranged from 0.0001 to 0.0007. Conversely, the Eau Fraiche sample, containing the highest alcohol concentration, exhibited absorbance values ranging from 0.0021 to 0.0028. Based on these findings, it can be concluded that a higher alcohol concentration results in a higher absorbance value, and vice versa. Keywords: Alcohol, InGaAs Photodiode, Patchouli oil

Item Type: Thesis (Bachelor)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Jurusan Teknologi Industri dan Proses > Teknik Elektro
Depositing User: Russel Amanda Simangunsong
Date Deposited: 09 Jan 2026 08:12
Last Modified: 09 Jan 2026 08:12
URI: http://repository.itk.ac.id/id/eprint/25107

Actions (login required)

View Item View Item