Perbandingan Performa Kekuatan H-Beam dengan Circullar Hollow Pillar pada kasus Tongkang 300 FT

Mahmud, Muhammad Aksan (2026) Perbandingan Performa Kekuatan H-Beam dengan Circullar Hollow Pillar pada kasus Tongkang 300 FT. Bachelor thesis, Institut Teknologi Kalimantan.

[img] Text
09211031_abstract_en.pdf
Restricted to Repository staff only until 25 April 2028.

Download (337kB) | Request a copy
[img] Text
09211031_abstract_id.pdf
Restricted to Repository staff only until 25 April 2028.

Download (361kB) | Request a copy
[img] Text
09211031_approval_sheet.pdf
Restricted to Repository staff only until 25 April 2028.

Download (425kB) | Request a copy
[img] Text
09211031_bibliography.pdf
Restricted to Repository staff only until 25 April 2028.

Download (344kB) | Request a copy
[img] Text
09211031_chapter_1.pdf
Restricted to Repository staff only until 25 April 2028.

Download (409kB) | Request a copy
[img] Text
09211031_chapter_2.pdf
Restricted to Repository staff only until 25 April 2028.

Download (652kB) | Request a copy
[img] Text
09211031_chapter_3.pdf
Restricted to Repository staff only until 25 April 2028.

Download (347kB) | Request a copy
[img] Text
09211031_chapter_4.pdf
Restricted to Repository staff only until 25 April 2028.

Download (2MB) | Request a copy
[img] Text
09211031_conclusions.pdf
Restricted to Repository staff only until 25 April 2028.

Download (355kB) | Request a copy
[img] Text
09211031_cover.pdf
Restricted to Repository staff only until 25 April 2028.

Download (539kB) | Request a copy
[img] Text
09211031_enclosure.pdf
Restricted to Repository staff only until 25 April 2028.

Download (548kB) | Request a copy
[img] Text
09211031_illustrations.pdf
Restricted to Repository staff only until 25 April 2028.

Download (328kB) | Request a copy
[img] Text
09211031_notations.pdf
Restricted to Repository staff only until 25 April 2028.

Download (327kB) | Request a copy
[img] Text
09211031_paper.pdf
Restricted to Repository staff only until 25 April 2028.

Download (879kB) | Request a copy
[img] Text
09211031_table_of_content.pdf
Restricted to Repository staff only until 25 April 2028.

Download (367kB) | Request a copy
[img] Text
09211031_tables.pdf
Restricted to Repository staff only until 25 April 2028.

Download (335kB) | Request a copy
[img] Text
09211031_statement_of_authenticity.pdf
Restricted to Repository staff only until 25 April 2028.

Download (128kB) | Request a copy
[img] Text
09211031_publishing_agreement.pdf
Restricted to Repository staff only until 25 April 2028.

Download (142kB) | Request a copy
[img] Text
09211031_preface.pdf
Restricted to Repository staff only until 25 April 2028.

Download (285kB) | Request a copy
[img] Text
09211031_Form. TA-020.pdf
Restricted to Repository staff only until 25 April 2028.

Download (283kB) | Request a copy
[img] Text
09211031_presentation.pdf
Restricted to Repository staff only until 25 April 2028.

Download (872kB) | Request a copy

Abstract

Penelitian ini dilatarbelakangi oleh kebutuhan akan elemen struktur yang kuat dan efisien pada tongkang (barge) dengan panjang 300 ft, khususnya pada sistem pilar penyangga geladak. Pilar H-Beam telah lama digunakan karena kekuatan dan stabilitasnya, sementara Circular Hollow Pillar (CHP) menawarkan keunggulan dalam distribusi beban serta potensi ketahanan terhadap korosi. Permasalahan utama penelitian ini adalah membandingkan kinerja kekuatan kedua jenis pilar tersebut berdasarkan respon tegangan yang terjadi akibat pembebanan tertentu pada tongkang. Metode penelitian yang digunakan adalah simulasi numerik menggunakan Finite Element Method (FEM) dengan perangkat lunak ANSYS. Analisis dilakukan pada bagian void tank tongkang 300 ft dengan memodelkan pilar H-Beam dan Circular Hollow Pillar. Pembebanan statis diterapkan sebesar 15 ton/m², yang merepresentasikan beban muatan dan geladak, serta evaluasi dilakukan sesuai aturan klasifikasi Biro Klasifikasi Indonesia (BKI). Hasil analisis menunjukkan bahwa pilar H-Beam menghasilkan tegangan maksimum sebesar 51,922 MPa (vertikal) dan 47,307 MPa (diagonal), sedangkan Circular Hollow Pillar menunjukkan tegangan maksimum, yaitu 56,24 MPa (vertikal) dan 52,818 MPa (diagonal). Circular Hollow Pillar mengalami tegangan 7,69% lebih besar dibandingkan H-Beam pada kondisi beban yang sama dan relatif masih aman karena belum melewati tegangan luluh material. Pilar H-Beam memiliki kinerja kekuatan yang lebih baik dibandingkan Circular Hollow Pillar, n-amun, Circular Hollow Pillar berpotensi mengurangi penggunaan material karena luas penampangnya yang lebih kecil.

Item Type: Thesis (Bachelor)
Subjects: T Technology > TH Building construction
Divisions: Jurusan Sains, Teknologi Pangan, dan Kemaritiman > Teknik Perkapalan
Depositing User: Muhammad Aksan Mahmud
Date Deposited: 15 Jan 2026 05:20
Last Modified: 15 Jan 2026 05:20
URI: http://repository.itk.ac.id/id/eprint/25393

Actions (login required)

View Item View Item