Putra, Juliade (2024) ANALISIS DOSIS RADIASI BAGIAN DADA PADA ALAT CATHLAB TANPA FILTER MENGGUNAKAN SIMULASI METODE MONTE CARLO -Submit Jurnal. Bachelor thesis, Institut Teknologi Kalimantan.
Text
01171018_Cover.pdf Restricted to Registered users only until 2025. Download (311kB) | Request a copy |
|
Text
01171018_statement_of_authenticity.pdf Restricted to Registered users only until 2025. Download (494kB) | Request a copy |
|
Text
01171018_publishing_agreement.pdf Restricted to Registered users only until 2025. Download (541kB) | Request a copy |
|
Text
01171018_approval_sheet.pdf Restricted to Registered users only until 2025. Download (484kB) | Request a copy |
|
Text
01171018_preface.pdf Restricted to Registered users only until 2025. Download (121kB) | Request a copy |
|
Text
01171018_abstract_id.pdf Restricted to Registered users only until 2025. Download (137kB) | Request a copy |
|
Text
01171018_abstract_en.pdf Restricted to Repository staff only until 2025. Download (18kB) | Request a copy |
|
Text
01171018_table_of_content.pdf Restricted to Repository staff only until 2025. Download (128kB) | Request a copy |
|
Text
01171018_illustrations.pdf Restricted to Repository staff only until 2025. Download (232kB) | Request a copy |
|
Text
01171018_tables.pdf Restricted to Repository staff only until 2025. Download (227kB) | Request a copy |
|
Text
01171018_chapter_1.pdf Restricted to Repository staff only until 2025. Download (133kB) | Request a copy |
|
Text
01171018_chapter_2.pdf Restricted to Repository staff only until 2025. Download (899kB) | Request a copy |
|
Text
01171018_chapter_3.pdf Restricted to Repository staff only until 2025. Download (295kB) | Request a copy |
|
Text
01171018_chapter_4.pdf Restricted to Repository staff only until 2025. Download (1MB) | Request a copy |
|
Text
01171018_chapter_5.pdf Restricted to Repository staff only until 2025. Download (139kB) | Request a copy |
|
Text
01171018_bibliography.pdf Restricted to Registered users only until 2025. Download (139kB) | Request a copy |
|
Text
01171018_enclosure.pdf Restricted to Repository staff only until 2025. Download (28kB) | Request a copy |
|
Text
01171018_paper.pdf Restricted to Repository staff only until 2025. Download (730kB) | Request a copy |
|
Text
01171018_presentation.pdf Restricted to Repository staff only until 2025. Download (1MB) | Request a copy |
|
Text
01171018_form.TA-020.pdf Restricted to Repository staff only until 2025. Download (475kB) | Request a copy |
Abstract
Radiodiagnostik pada Laboratorium Kateterisasi (cathlab) menggunakan sinar-X secara esensial untuk diagnosis penyakit kardiovaskular kompleks. Namun, penggunaan sinar-x dengan paparan berulang dapat meningkatkan risiko efek samping jangka panjang. Pemahaman distribusi dosis radiasi pada pasien menjadi krusial, dan metode simulasi Monte Carlo umum digunakan. Hasil simulasi menunjukkan adanya sedikit perbedaan dalam spektrum sinar-X dari sumber tabung, dengan energi 0,05-0,01 MeV menghasilkan puncak fluks sebesar 6,2x10-3-9,27x10-3 partikel/cm2. Estimasi laju dosis radiasi diperoleh untuk rentang energi 0,05-0,1 MeV, dengan nilai tertinggi terjadi pada kulit depan, yaitu 0,46 mGy/s – 2,4 mGy/s. Estimasi laju dosis yang didapatkan sesuai dengan rekomendasi Bapeten yaitu tidak lebih dari 2,5 mGy/s pada kulit depan. Semakin tinggi energi yang digunakan, dosis serap yang dihasilkan juga semakin tinggi.
Item Type: | Thesis (Bachelor) |
---|---|
Subjects: | Q Science > QC Physics Q Science > QM Human anatomy |
Divisions: | Jurusan Sains, Teknologi Pangan, dan Kemaritiman > Fisika |
Depositing User: | Juliade Putra |
Date Deposited: | 27 Dec 2023 03:02 |
Last Modified: | 27 Dec 2023 03:02 |
URI: | http://repository.itk.ac.id/id/eprint/20778 |
Actions (login required)
View Item |