Pujayanto, Dimas Ari (2025) Analisis Kandungan Mikroorbiologi dam Higiene Sanitasi Depot Air Minum Isi Ulang (Studi Kasus: Karang Joang, Kota Balikpapan). Bachelor thesis, Institut Teknologi Kalimantan.
Text
13201022_cover.pdf Restricted to Repository staff only until 10 May 2027. Download (722kB) | Request a copy |
|
Text
13201022_statement_of_aunthenticity.pdf Restricted to Repository staff only until 10 May 2027. Download (363kB) | Request a copy |
|
Text
13201022_publishing_agreement.pdf Restricted to Repository staff only until 10 May 2027. Download (390kB) | Request a copy |
|
Text
13201022_approval_sheet.pdf Restricted to Repository staff only until 10 May 2027. Download (358kB) | Request a copy |
|
Text
13201022_preface.pdf Restricted to Repository staff only until 10 May 2027. Download (427kB) | Request a copy |
|
Text
13201022_abstract_id.pdf Restricted to Repository staff only until 10 May 2027. Download (486kB) | Request a copy |
|
Text
13201022_abstract_en.pdf Restricted to Repository staff only until 10 May 2027. Download (532kB) | Request a copy |
|
Text
13201022_table_of_content.pdf Restricted to Repository staff only until 10 May 2027. Download (489kB) | Request a copy |
|
Text
13201022_illustrations.pdf Restricted to Repository staff only until 10 May 2027. Download (426kB) | Request a copy |
|
Text
13201022_tables.pdf Restricted to Repository staff only until 10 May 2027. Download (430kB) | Request a copy |
|
Text
13201022_notations.pdf Restricted to Repository staff only until 10 May 2027. Download (425kB) | Request a copy |
|
Text
13201022_chapter_1.pdf Restricted to Repository staff only until 10 May 2027. Download (506kB) | Request a copy |
|
Text
13201022_chapter_2.pdf Restricted to Repository staff only until 10 May 2027. Download (769kB) | Request a copy |
|
Text
13201022_chapter_3.pdf Restricted to Repository staff only until 10 May 2027. Download (1MB) | Request a copy |
|
Text
13201022_chapter_4.pdf Restricted to Repository staff only until 10 May 2027. Download (1MB) | Request a copy |
|
Text
13201022_conclusions.pdf Restricted to Repository staff only until 10 May 2027. Download (487kB) | Request a copy |
|
Text
13201022_bibliography.pdf Restricted to Repository staff only until 10 May 2027. Download (444kB) | Request a copy |
|
Text
13201022_enclosure.pdf Restricted to Repository staff only until 10 May 2027. Download (8MB) | Request a copy |
|
Text
13202022_paper.pdf Restricted to Repository staff only until 10 May 2027. Download (326kB) | Request a copy |
|
Text
13201022_Form. TA-020.pdf Restricted to Repository staff only until 10 May 2027. Download (317kB) | Request a copy |
|
Text
13201022_presentation.pdf Restricted to Repository staff only until 10 May 2027. Download (1MB) | Request a copy |
|
Text
13201022_cover.pdf Restricted to Repository staff only until 10 May 2027. Download (501kB) | Request a copy |
Abstract
Depot air minum isi ulang (DAMIU) mengolah air baku menjadi air minum dan menjualnya langsung kepada konsumen. Pengawasan DAMIU tidak dilakukan secara berkala, sehingga tidak dapat menjamin keamanan produk yang diperjualbelikan. Konsumen harus memperhatikan masalah seperti kebersihan bangunan dan alat, pemeliharaan peralatan, dan operator. Higiene merupakan upaya kesehatan dengan memelihara dan melindungi kebersihan. Tujuan penelitian ini adalah untuk menganalisis kondisi eksisting DAMIU berdasarkan higiene sanitasi di Kelurahan Karang Joang Kota Balikpapan dan menganalisis kualitas air baku dan air minum berdasarkan higiene sanitasi DAMIU serta hubungan antara higiene sanitasi dengan kualitas air minum. Mettode penelitian, analisis deskriptif pendekatan kuantitatif. Jumlah sampel yang diambil ialah 11 DAMIU. Dilakukan uji kualitas air berdasarkan parameter Escherichia Coli dan Total Coliform menggunakan metode CFU (Colony Forming Unit). Kondisi eksisting ditemukan permasalahan yang terjadi pada indikator bangunan depot, alat produksi dan operator. Kandungan air baku perameter Total Coliform rentang 8 – 138 CFU/100 mL parameter E. Coli rentang 2 – 103 CFU/100 mL Kandungan air minum pada Total Coliform rentang 1 - 30 CFU/100 mL pada E. Coli rentang 1 – 9 CFU/100 mL. Hubungan sanitasi depot, alat produksi, proses pengemasan dan higiene perorangan sangat rendah rentang 0,202 – 0,274.
Item Type: | Thesis (Bachelor) |
---|---|
Subjects: | Q Science > Q Science (General) Q Science > QR Microbiology T Technology > TD Environmental technology. Sanitary engineering |
Divisions: | Jurusan Ilmu Kebumian dan Lingkungan > Teknik Lingkungan |
Depositing User: | Dimas Ari Pujayanto |
Date Deposited: | 09 Jan 2025 07:39 |
Last Modified: | 09 Jan 2025 07:39 |
URI: | http://repository.itk.ac.id/id/eprint/21952 |
Actions (login required)
View Item |